Study of High K.V Technique in Chest X-ray - SUST Repository
文章推薦指數: 80 %
Then the collected data correlated with K.V (High & low K.V). The results showed that the use of high K.V techniques is excellent in revealing the heart, hilar ... SUSTRepository StudyofHighK.VTechniqueinChestX-ray Login SUSTHome → ThesesandDissertations → CollegeofMedicalRadiologicScience → MastersDissertations:MedicalRadiologicScience → ViewItem JavaScriptisdisabledforyourbrowser.Somefeaturesofthissitemaynotworkwithoutit. StudyofHighK.VTechniqueinChestX-ray Siddig,RayaHassan;Supervisor-DohaAbdoMohammedAbdo URI: http://repository.sustech.edu/handle/123456789/2725 Date: 2010-12-01 Abstract: Thechestradiographsremainasoneofthemostcommonlyperformedexamination,withconsiderablerepetitioninmanyhospitalinKhartoum,that’sduetopoorselectionofexposurefactors(K.V–mAs).Theselectionofthesefactorsdependsontheexperienceofthetechnologistandtheanatomicalstructurestoberevealed. TheresearcherstudiedtheuseofhighK.VtechniqueinPACXRtoevaluateitsroletoclarifythevariousanatomicalstructuresinthechestandtoevaluatetheimagequalityoftheimagesdonewithhighK.V. Thestudyconsistedof60patientsexaminedbyPACXR.30ofthemexaminedwithhighK.Vandtheother30withlowK.Vthecollecteddataincludesage,sex,clinicaldiagnosis,anatomicalstructures,andX-rayfindings,fortheimagequalityinthecollecteddatagroupcontrast,sharpnessandtheresolution.ThenthecollecteddatacorrelatedwithK.V(High&lowK.V). TheresultsshowedthattheuseofhighK.Vtechniquesisexcellentinrevealingtheheart,hilarregion,lymphnodesandgreatvessels,whilereducingtheappearanceofthebonevisibility.Intheimagequality,theresultshowedthatcontrastinhighK.VwaslowwhileincreasingthedegreeofsharpnessandresolutionincomparisonwiththelowK.Vimages. Description: Thesis Showfullitemrecord Filesinthisitem Name: StudyofHighK.V... Size: 62.70Kb Format: PDF Description: Title View/Open Name: Abstract.pdf Size: 95.39Kb Format: PDF Description: Abstract View/Open Name: Research.pdf Size: 897.7Kb Format: PDF Description: Research View/Open Name: AppendixA.pdf Size: 68.62Kb Format: PDF Description: Appendix View/Open Name: AppendixB.pdf Size: 1.783Mb Format: PDF Description: Appendix View/Open Name: AppendixC.pdf Size: 740.0Kb Format: PDF Description: Appendix View/Open ThisitemappearsinthefollowingCollection(s) MastersDissertations:MedicalRadiologicScience[1317] Share SearchSUST SearchSUST ThisCollection Browse AllofDSpace Communities&Collections ByIssueDate Authors Titles Subjects ThisCollection ByIssueDate Authors Titles Subjects MyAccount Login Register DSpacesoftwarecopyright © 2002-2016 DuraSpace Themeby ContactUs|SendFeedback
延伸文章資訊
- 1High-kV technique - Medical Dictionary
- 2Technical Factors of Radiology
* time: how long the exposure lasts. Understanding Technique. kVp stands for kilovoltage peak.116...
- 3Effect of Changing X-ray Tube Voltage (kV) | Radiology
This image was generated at 60 kV, and required a relatively high radiation intensity of 141 mAs....
- 4(PDF) High kilovoltage digital exposure techniques and ...
When the kVp was increased in 15% increments and mAs divided by half, the radiation dose to the g...
- 5An evaluation of the effect of tube potential on clinical image ...
High tube potential, or 'high-kVp' techniques, which were established using traditional film-scre...