kVP Accuracy - Quality control in radiography
文章推薦指數: 80 %
There are guidelines set by H.A.R.P. and S.C. 35 to ensure an appropriate range of kVp accuracy. H.A.R.P. sets the accuracy at ±8% while S.C. 35 ... Qualitycontrolinradiography About ClusterOne HalfValueLayer EICalibration VisualInspection Film/ScreenContact GridAlignment CRErasure ClusterTwo LightFieldCongruencyTest TimerAccuracy kVpAccuracy LimitingSpatialResolution CRUniformity DR(QAP) ClusterThree Reproducibility ThresholdContrastDetailDetectabilityCR&DR CRDarkNoise Linearity Mammography Contact QUALITYCONTROLINRADIOGRAPHY kVPAccuracy 2/28/2015 0Comments MICHELLEFERDERBAR1217500Kilovoltpeak(kVp)isatechnicalfactorsetbythetechnologistwhenperformingx-rays.Itspurposeistosetthepenetratingpowerofthex-raysorthequalityofthebeam.Thenumbersetisthehighestamountofenergythatanx-rayphotoncouldhaveleavingthetube.ItisimportantthatthekVpsettingreflectswhatisactuallycomingoutofthetubetoensurereproducibility.Thislabwasconductedinx-rayroom4andx-rayroom3,B114oftheInstituteofAppliedHealthSciencesontheMcMasterUniversityCampus.Figure1.ThesetupforthekVpaccuracytest.Theprocedurewasfairlysimple.WesettheSIDto70cmandcollimatedtotheentiretyofthesensor.Wetookthreeexposureseachat60kVp,81kVp,and102kVpat5mAs.WetookanotherthreeexposureseachattheaforementionedkVpsbutat16mAs.WeusedtheCobiaSmartx-raymetertodeterminethekVpvaluesinRoom4andadifferentmeterinroom3.Whenwetooktheseexposures,wewaitedroughly30secondsbetweeneachexposuretopreventtubeoverload.Table1.kVpreadingsandaveragesobtainedfromRoom3.kVpmAsValue1Value2Value3AveragekVpPercentageDifference60551.8351.5051.3551.56-14.07601651.3251.3551.2551.31-14.4881578.9379.1779.3579.15-2.28811679.1379.1979.1279.15-2.28102598.5498.0198.0698.20-3.731021699.5698.7998.6198.99-2.95Table2.kVpreadingsandaveragesobtainedfromRoom4.kVpmAskVp1kVp2kVp3AveragekVpPercentageDifference60560.0760.1760.2360.16+1.93601660.1560.1660.2260.18+1.9781580.9581.0180.9780.98+1.23811681.1481.1081.1181.12+1.401025101.6101.6101.7101.6-0.3610216101.9101.9101.8101.9-0.13ThereareguidelinessetbyH.A.R.P.andS.C.35toensureanappropriaterangeofkVpaccuracy.H.A.R.P.setstheaccuracyat±8%whileS.C.35setsitat±10%.Papp(2011)isthemoststrictwith±5%.Inroom4,allkVpsettingspass.Inroom3,60kVpat5mAsand60kVpat16mAsfailbyallstandards.SomepossiblereasonsforthisarethatthereaderwaslesssensitivetothislowerkVpsetting,theunithasfaultycircuitry,thehighvoltagetransformermaybemalfunctioning,theautotransformermayhaveanissue,orthesupplytothegeneratorisnotthegreatest(Stelmark,2010).ItisveryimportantthatkVpaccuracyismaintainedtoensurethatthedesiredtechniqueiscomingoutofthetube.SincekVpcontrolsbothx-raybeamqualityandquantity,havingtheincorrectkVpexitingthetubemayresultinfailingtofollowtheALARAprincipleandoverdosingourpatient.Thistestshouldbeperformedannually(Papp,2011). ReferencesHealthCanada.(2008). Safetycode35:Safetyproceduresfortheinstallation,useand controlofx-rayequipmentinlargemedicalradiologicalfacilities. Retrieved fromhttp://www.hc-sc.gc.ca.Papp,J.(2011).Qualitymanagementintheimagingsciences(4thed.).St.Louis, Mo.:MosbyElsevier.ServiceOntario.(2011). HealingArtsRadiationProtectionAct.Retrieved from http://www.e-laws.gov.on.ca/html/regs/english/elaws_regs_900543_e.htm.Stelmark,J.(2010).AppliedQualityManagement:kVpAccuracyandReproducibility. Retrievedfromhttp://profstelmark.com/QA_new/report%20sample.pdf. 0Comments LeaveaReply. Michelleferderbar Asastudentradiographercurrentlyinher3rdyearatMohawk-McMasterMedicalRadiationSciencesprogram,MichellespentherfirstclinicalplacementatJuravinskiHospitalinHamilton,Ontario.There,shehadtheopportunitytoexperiencequalitycontrolroutinesdonebytheprofessionals.Sheisthrilledattheopportunitytolearnthereasonsandtheoriesbehindthem. Archives February2015 Categories All RSSFeed Poweredby Createyourownuniquewebsitewithcustomizabletemplates. GetStarted
延伸文章資訊
- 1The Role Of kVp Accuracy Of Diagnostic X-Ray Units And ...
We propose as practical acceptance test criteria that mR/mas variation on each unit for all curre...
- 2Radiological kVp accuracy, reproducibility and consistence ...
Optimization in X-ray imaging in order to reduce patient dose during diagnostics X-ray examinatio...
- 3Quality Assurance for Radiographic X-Ray Units and ...
The kVp across an x-ray tube is affected by the tube current, and ... Objective of Test: To verif...
- 4Assessment of peak kilovoltage accuracy in ten selected X-ray ...
Results: The kVp accuracy test for X-ray units D 1 , D 2 , D 5 , D 6 , D 7 , and D 8 were within ...
- 5Q.A. Collectible